Robustel GoRugged R3000 User Guide
RT_UG_R3000_v.2.0.0 17.01.2014 53 / 131
Confidential
Modbus

ASCII 
Slave Address @
Modbus Slave
This connection is usually used to connect to the Modbus slave devices
which as TCP server. Enter IP address of the TCP server.
Null
Slave Port @ Modbus
Slave
Enter the port number of TCP server.
Null
ID @ Modbus Slave
Enter the ID number of TCP server.
Null
Interval Timeout @
Transparent Over
Rlink
Serial port will queue the data in buffer and then send it to the Cellular
WAN/Ethernet WAN when it reaches the Interval Timeout in this field.
10
Attached serial device
type @ Modbus Over
Rlink
 ASC .
Modbus RTU slave: router connects to slave device which works under
Modbus RTU protocol.
Modbus ASC slave: router connects to slave device which works under
Modbus ASCprotocol.
Modbus
RTU slave
3.15 Configuration -> DI/DO
This section allows users to set the DI/DO parameters.
DI @ DI/DO
Item
Description
Default