RobustelGoRuggedM1000ProUserGuide
RT_M1000Pro_UG_v01.01 27.12.2011 46/59
Confidential
Chapter5. Appendix
5.1 FactorySettings
FactorysettingofthemodemCOMportunderConfigModeandNormalModeis:
Databits=8
Parity=none
Stopbits=1
Baud=115200bps
Flowcontrol=none
5.2 RestoretoFactoryDefault
ThemodemcouldberestoredtofactorydefaultbyModemConfiguratorPro,SMSorhardwareoperation.
Followingstepsindicatehowtorestoretofactorydefaultbyhardwareoperation:
1. SetthemodemunderConfigMode,poweronthemodem;
2. ChangethemodemtoNormalMode,within 2se conds,changethemodemfromNormalModetoConfigMode;
3. Restoresuccessfully.
Note:PINsetting,PhoneBooksettingsandCOMsettingswillnotberestoredtofactorydefault.
5.3 SMSCommandsforRemoteControl
M1000ProsupportsremoteconfigurationandremotemodemstatusreadingviaSMS.
AnSMScommandhasfo llowingstructure:
Password:cmd1,a,b,c;cmd2,d,e,f;cmd3,g,h,i;...;cmdn,j,k,n
Note:
1. Password: SMS control password is configured at Basic‐>SMS Control‐>Password, which is an optional
parameter.
Whenthereisnopassword,SMScommandhasfollowingstructure:cmd1;cmd 2;cmd3;…;cmdn
Whenthereisapassword,SMScommandhasfollowingstructure:Password:cmd1;cmd2;cmd3;…;cmdn
2. Cmd1,cmd2,cmd3toCmdn,whichare commandidentificationnumber0000–9999
3. A,b,cton,whicharecommandparameters
4. Thesemicoloncharacter(‘;’)isusedtoseparatemorethanonecommandspack edinasingleSMS.
5. AftersettingnewparametersforM1000Pro,pleaseuse0004commandtosaveparametersandresetthemodem,
thenthenewparameterswilltakeeffect.
6. E.g.,1234:1001,M1000Pro;0004
Inthiscommand,passwordis1234,andwesetdevicenameas“M1000Pro”,thensaveparametersandresetthe